3VA2716-5CF12-0AA0-Z F03+T30
SIEMENS ⍾ 3VA27165CF120AA0ZF03T30
Fixed-mounted molded case circuit breaker w. handle frame 1600; 4AUX and trip alarm switch S24; Icu "M" Icu=55kA @ 415V, 4-pole, left ETU660, LSIG, In=1600A display, meas., comm. function Ir=640...1600A Isd=0.6...10xIn, Ii=1.5...15xIn N conductor protec. adjustable OFF, 50%, 100%, 150%, 200% gr.-fault prot., can be sw. off Ig=0.1...1 x In, tg=0.1 - 1.0s rear horizontal connection With optional communication connection including integrated breaker connect 24 V DC module, actuator COM ACT, COM RTC and COM PSS(as draw-out version) with Metering MF Basic for energy monitoring Voltage tap at the bottom Without additional alarm switch assembly With mechanical calling without 2nd auxiliary release without 1st auxiliary release F03= Communication module COM041 PROFINET Gateway T30= Door sealing frame IP30 for fixed-mounted circuit breaker
SIEMENS 3VA2716-5CF12-0AA0-Z F03+T30 Datasheet PDF (en) Tamaño: 147 KB |
Descarga |
Relacionado 3va27 / 3VA2/3VA3 ⍾ Página 2
-
3VA2712-1AC25-4AB0
Fixed-mounted molded case circuit breaker frame 1600; with RTC and 4AUX trip alarm switch S24; Icu "M" Icu=55kA @ 415V, 4-pole, right ETU350, LSI, In=1250A rotary coding switch Ir= …
-
3VA2712-2BE31-0BA1
Draw-out molded case circuit breaker with guide frame and PSS frame 1600; with RTC and 4AUX trip alarm switch S24; Icu "H" Icu=85kA @ 415V, 3-pole ETU650, LSI, In=1250A display, me …
-
3VA2712-3AC05-0AA0
Fixed-mounted molded case circuit breaker frame 1600; with RTC and 4AUX trip alarm switch S24; Icu "C" Icu=110kA @ 415V, 3-pole ETU350, LSI, In=1250A rotary coding switch Ir=500... …
-
3VA2712-5AA01-0AA0
Fixed-mounted sw. disconnector with handle frame 1600; 4AUX Icu=55kA @ 415V, 3-pole SD100; In=1250A without overload protection w/o short-circuit protection rear vertical connectio …
-
3VA2712-5AA03-0AA0
Fixed-mounted sw. disconnector with handle frame 1600; 4AUX Icu=55kA @ 415V, 3-pole SD100; In=1250A without overload protection w/o short-circuit protection nut keeper kit No commu …
-
3VA2712-5AB03-0AA0
Fixed-mounted molded case circuit breaker w. handle frame 1600; 4AUX and trip alarm switch S24; Icu "M" Icu=55kA @ 415V, 3-pole ETU320, LI, In=1250A rotary coding switch Ir=500...1 …
-
3VA2712-5AB03-0AA1
Fixed-mounted molded case circuit breaker w. handle frame 1600; 4AUX and trip alarm switch S24; Icu "M" Icu=55kA @ 415V, 3-pole ETU320, LI, In=1250A rotary coding switch Ir=500...1 …
-
3VA2712-5AB05-0AA0
Fixed-mounted molded case circuit breaker w. handle frame 1600; 4AUX and trip alarm switch S24; Icu "M" Icu=55kA @ 415V, 3-pole ETU320, LI, In=1250A rotary coding switch Ir=500...1 …
-
3VA2712-5AB05-0AK0
Fixed-mounted molded case circuit breaker w. handle frame 1600; 4AUX and trip alarm switch S24; Icu "M" Icu=55kA @ 415V, 3-pole ETU320, LI, In=1250A rotary coding switch Ir=500...1 …
-
3VA2712-5AB06-0AA0
Fixed-mounted molded case circuit breaker w. handle frame 1600; 4AUX and trip alarm switch S24; Icu "M" Icu=55kA @ 415V, 3-pole ETU320, LI, In=1250A rotary coding switch Ir=500...1 …
-
3VA2712-5AB13-0AA0
Fixed-mounted molded case circuit breaker w. handle frame 1600; 4AUX and trip alarm switch S24; Icu "M" Icu=55kA @ 415V, 4-pole, left ETU320, LI, In=1250A rotary coding switch Ir=5 …
-
3VA2712-5AC03-0AH0
Fixed-mounted molded case circuit breaker w. handle frame 1600; 4AUX and trip alarm switch S24; Icu "M" Icu=55kA @ 415V, 3-pole ETU350, LSI, In=1250A rotary coding switch Ir=500... …