3AH3305-2ME40-0EB2 SIEMENS ⍾ 3AH33052ME400EB2
Vacuum Circuit-Breaker 36kV pole-centre distance 350mm 31.5KA 1250A operatg.mechan. EK secondary equipment: operating cycle counter breaker tripping signal 2 position switches for signal: "closing spring charged" closing solenoid with varistor circuitry in the secundary circuit 1 shunt release voltage of closing solenoid DC 110V voltage of 1st shunt release DC 110V without 2nd release without 3rd release voltage of operating mechanism DC 110V auxiliary switch 6NO+6NC secondary connection 64-pole plug connector mechanical interlocking rating plate and instructions in english, frequency of secondary voltage 50Hz; ;
Relacionado 3AH ⍾ Página 1
-
-
3AH3128-2PF55-0FD9-Z A46
+E13 +F20 +F30 +R1G Vacuum Circuit-Breaker 12kV pole-centre distance 275mm 63kA 1250A operatg.mechanism EU secondary equipment: operating cycle counter breaker tripping signal 2 position switches for …
-
3AH3228-7NF55-0FD2-Z E13
+F20 +F30 Interruptor automático en vacío 17,5kV Distancia entre centros de polos 275 mm 63kA 3150A accionamiento EU Equipamiento de secundario: contador de ciclos de maniobras aviso de disp …
-
3AH3305-7NE40-0EA2
Interruptor automático en vacío 36kV Distancia entre centros de polos 350 mm 31,5kA 3150A accionamiento EK Equipamiento de secundario: contador de ciclos de maniobras aviso de disp …
-
3AH3305-8NE40-0EA2
Interruptor automático en vacío 36kV Distancia entre centros de polos 350 mm 31,5kA 4000A accionamiento EK Equipamiento de secundario: contador de ciclos de maniobras aviso de disp …
-
3AH4254-2RE44-0ED2-Z F20
+F30 +M60 Vacuum Circuit-Breaker 24kV pole-centre distance 210mm 25kA 1250A operat.mechan.EU secondary equipment: operating cycle counter breaker tripping signal 2 position switches for sign …
-
3AH4266-6ME40-0ED3-Z F20
+F30 Vacuum circuit breaker 24 kV for 120,000 mech. switching cycles Distance between pole centers 275 mm 40 kA 2500 A operating mechanism EU Secondary equipment: switching cycle counte …
-
3AH4266-6RE44-0ED2-Z F20
+F30 Vacuum circuit breaker 24 kV for 120,000 mech. switching cycles Distance between pole centers 275 mm 40 kA 2500 A operating mechanism EU Secondary equipment: switching cycle counte …
-
3AH4305-2HK88-8KC2
VACUUM CIRCUIT-BREAKER 36KV F.120.000 MECH.OPERATING CYCLES POLE-CENTRE DISTANCE 350MM 31.5KA 1250A OPERATG.MECHAN. EK SECONDARY EQUIPMENT: OPERATING CYCLE COUNTER BREAKER TRIPPING …
-
3AH4305-2HK88-8KC2-Z E13
+E14 +E15 +F20 +F30 Vacuum Circuit-Breaker 36kV f.120.000 mech.operating cycles pole-centre distance 350mm 31.5kA 1250A operat.mechan.EK secondary equipment: operating cycle counter breaker tripping s …
-
3AH4305-4AB10-0AA0
VACUUM CIRCUIT-BREAKER 36KV F.120.000 MECH.OPERATING CYCLES POLE-CENTRE DISTANCE 350MM 31.5KA 2000A OPERATG.MECHAN. EK SECONDARY EQUIPMENT: OPERATING CYCLE COUNTER BREAKER TRIPPING …
-
3AH4305-4TK88-8KC2
VACUUM CIRCUIT-BREAKER 36KV F.120.000 MECH.OPERATING CYCLES POLE-CENTRE DISTANCE 350MM 31.5KA 2000A OPERATG.MECHAN. EK SECONDARY EQUIPMENT: OPERATING CYCLE COUNTER BREAKER TRIPPING …