234-1BD60 Yaskawa ⍾ 2341BD60
234-1BD60 - Signal modules analog | Analog in/output modules; Order no. : 234-1BD60; Type : SM 234; Features : 4x AI2x AO 12 Bit Voltage +/- 10 V, 1…5 V, 0…10 V Current +/- 20 mA, 0/4…20 mA Resistance thermometer Parameterizable; Current consumption from backplane bus : 100 mA; Power loss : 2.9 W; Number of inputs : 4; Cable length, shielded : 200 m; Rated load voltage : DC 24 V; Reverse polarity protection of rated load voltage : Current consumption from load voltage L+ (without load) : 70 mA; Voltage inputs : Min. input resistance (voltage range) : 120 kΩ; Input voltage ranges : +1 V ... +5 V0 V ... +10 V-10 V ... +10 V-400 mV ... +400 mV-4 V ... +4 V; Operational limit of voltage ranges : +/-0.3% ... +/-0.7%; Basic error limit voltage ranges : +/-0.2% ... +/-0.5%; Destruction limit voltage : max. 15V; Current inputs : Max. input resistance (current range) : 90 Ω; Input current ranges : +4 mA ... +20 mA0 mA ... +20 mA-20 mA ... +20 mA; Operational limit of current ranges : +/-0.3% ... +/-0.8%; Basic error limit current ranges : +/-0.2% ... +/-0.5%; Destruction limit current inputs (electrical current) : max. 50mA; Destruction limit current inputs (voltage) : max. 15V; Resistance inputs : Resistance ranges : 0 ... 600 Ohm0 ... 3000 Ohm; Operational limit of resistor ranges : +/-0.4%; Basic error limit : +/-0.2%; Destruction limit resistance inputs : max. 15V; Resistance thermometer inputs : Resistance thermometer ranges : Pt100Pt1000Ni100Ni1000; Operational limit of resistance thermometer ranges : +/-0.4% ... +/-1.0%; Basic error limit thermoresistor ranges : +/-0.2% ... +/-0.5%; Destruction limit resistance thermometer inputs : max. 15V; Technical unit of temperature measurement : °C; Resolution in bit : 16; Measurement principle : Sigma-Delta; Basic conversion time : 7 ms - 272 ms; Noise suppression for frequency : 50 Hz and 60 Hz; Initial data size : 4 Byte; Number of outputs : 2; Cable length, shielded : 200 m; Rated load voltage : DC 24 V; Reverse polarity protection of rated load voltage : Current consumption from load voltage L+ (without load) : 70 mA; Voltage output short-circuit protection : Voltage outputs : Min. load resistance (voltage range) : 1 kΩ; Max. capacitive load (current range) : 1 µF; Max. inductive load (current range) : 30 mA; Output voltage ranges : -10 V ... +10 V+1 V ... +5 V0 V ... +10 V; Operational limit of voltage ranges : +/-0.4% ... +/-0.8%; Basic error limit voltage ranges : +/-0.2% ... +/-0.4%; Destruction limit against external applied voltage : max. 15V; Current outputs : Max. in load resistance (current range) : 500 Ω; Max. inductive load (current range) : 10 mH; Typ. open circuit voltage current output : 13 V; Output current ranges : -20 mA ... +20 mA+4 mA ... +20 mA0 mA ... +20 mA; Operational limit of current ranges : +/-0.3% ... +/-0.8%; Basic error limit current ranges : +/-0.2% ... +/-0.5%; Destruction limit against external applied voltage : max. 15V; Settling time for ohmic load : 0.3 ms; Settling time for capacitive load : 1 ms; Settling time for inductive load : 0.5 ms; Resolution in bit : 12; Conversion time : 1.5 ms/channel; Substitute value can be applied : yes; Output data size : 4 Byte; Status display : none; Interrupts : yes; Process alarm : no; Diagnostic interrupt : yes, parameterizable; Diagnostic functions : yes; Diagnostics information read-out : possible; Supply voltage display : none; Group error display : red SF LED; Channel error display : none; Between channels and backplane bus : Between channels and power supply : Max. potential difference between inputs (Ucm) : DC 4 V; Max. potential difference between inputs and Mintern (Uiso) : DC 75 V/ AC 50 V; Insulation tested with : DC 500 V; Input bytes : 8; Output bytes : 4; Parameter bytes : 18; Diagnostic bytes : 12; Material : PPE / PA 6.6; Mounting : Profile rail 35 mm; Dimensions (WxHxD) : 25.4 mm x 76 mm x 88 mm; Net weight : 100 g; Operating temperature : 0 °C to 60 °C; Storage temperature : -25 °C to 70 °C; UL certification : yes