3VA4110-6ED24-0AA0 SIEMENS ⍾ 3VA41106ED240AA0
Circuit breaker 3VA4 UL frame 125 breaking capacity class H 65kA @ 480 V 2-pole, line protection TM210, FTFM, In=100A overload protection Ir=100A fixed short-circuit protection Ii=10 x In clamp connection
SIEMENS 3VA4110-6ED24-0AA0 Produktdatenblatt PDF (en) Dateigröße: 578 KB |
Download |
Die Überreste in der Kategorie 3VA4/3VA5 ⍾ Seite 1
-
3VA4110-4ED24-0AA0
Circuit breaker 3VA4 UL Frame 125 breaking capacity class S 25 kA @ 480 V 2-pole, line protection TM210, FTFM, In=100 A overload protection Ir=100 A permanently set short-circuit …
-
3VA4110-4ED34-0AA0
Leistungsschalter 3VA4 UL Frame 125 Schaltvermögenklasse S 25kA @ 480 V 3-polig, Anlagenschutz TM210, FTFM, In=100A Überlastschutz Ir=100A fest eingestellt Kurzschlussschutz Ii=10 …
-
3VA4110-5ED34-0AA0
Leistungsschalter 3VA4 UL Frame 125 Schaltvermögenklasse M 35kA @ 480 V 3-polig, Anlagenschutz TM210, FTFM, In=100A Überlastschutz Ir=100A fest eingestellt Kurzschlussschutz Ii=10 …
-
3VA4110-6ED34-0AA0
Leistungsschalter 3VA4 UL Frame 125 Schaltvermögenklasse H 65kA @ 480 V 3-polig, Anlagenschutz TM210, FTFM, In=100A Überlastschutz Ir=100A fest eingestellt Kurzschlussschutz Ii=10 …
-
3VA4111-4ED14-0AA0
Circuit breaker 3VA4 UL frame 125 breaking capacity class S 25kA @ 277 V 1-pole, line protection TM210, FTFM, In=110A overload protection Ir=110A fixed short-circuit protection Ii …
-
3VA4111-4ED34-0AA0
Circuit breaker 3VA4 UL Frame 125 breaking capacity class S 25 kA @ 480 V 3-pole, line protection TM210, FTFM, In=110 A overload protection Ir=110 A permanently set short-circuit …
-
3VA4111-5ED34-0AA0
Circuit breaker 3VA4 UL Frame 125 breaking capacity class M 35 kA @ 480 V 3-pole, line protection TM210, FTFM, In=110 A overload protection Ir=110 A permanently set short-circuit …
-
3VA4111-6ED24-0AA0
Circuit breaker 3VA4 UL frame 125 breaking capacity class H 65kA @ 480 V 2-pole, line protection TM210, FTFM, In=110A overload protection Ir=110A fixed short-circuit protection Ii …
-
3VA4111-6ED34-0AA0
Circuit breaker 3VA4 UL frame 125 breaking capacity class H 65kA @ 480 V 3-pole, line protection TM210, FTFM, In=110A overload protection Ir=110A fixed short-circuit protection Ii …
-
3VA4112-4ED24-0AA0
Circuit breaker 3VA4 UL frame 125 breaking capacity class S 25kA @ 480 V 2-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii …
-
3VA4112-4ED34-0AA0
Leistungsschalter 3VA4 UL Frame 125 Schaltvermögenklasse S 25kA @ 480 V 3-polig, Anlagenschutz TM210, FTFM, In=125A Überlastschutz Ir=125A fest eingestellt Kurzschlussschutz Ii=10 …
-
3VA4112-5ED24-0AA0
Leistungsschalter 3VA4 UL Frame 125 Schaltvermögenklasse M 35kA @ 480 V 2-polig, Anlagenschutz TM210, FTFM, In=125A Überlastschutz Ir=125A fest eingestellt Kurzschlussschutz Ii=10 …